WEIGHT SCALE SETUP

ECR Weight Scale Hardware Requirements:
xWedge Supports many of the NCI Series ECR and Standard Weight Scales.

Serial Port Interface:
xWedge supports Weight Scales connected to a RS232C Serial Port. Use a true RS232C Serial Port Adapter. Many Consumer based home computers that customers try to use in a business environment do not come standard with genuine RS232C serial ports. USB serial ports are not true RS232C. USB to Serial Port converters tend to truncate data depending on the driver and chip set. If you use a USB to Serial converter make sure that it supports true RS232C standards, otherwise the weight scale may not work properly. We have had limited success with USB interfaced weight scales where the manufacturers scale port driver creates a virtual serial port.

Business Computers are typically designed to have genuine RS232C serial ports installed and will work perfectly with supported weight scales.

Setting Up an ECR Weight Scale:
Test the weight scale through the xWedge Diagnostics. Configure the Weight Scale port so that it matches the proper Serial Port Number and verify you have had a successful test.
Proper Output Example for an NCI 6720 ECR Mode:
(10)00.430LB(13)(10)S00(13)(3)

ECR Weight Scale Test:
xWedge - Weight Scale Proper Computer Output in Diagnostic Mode
Click for Larger Image
Weight Scale Screen:
xWedge - Weight Scale Proper Computer Output in Capture Mode
Click for Larger Image
UN-Supported (wrong) Output for an NCI 6720 ECR Mode:
(10)00.430L
B(13)(10)S00(13)(3)

Note: Some scales send large packets of data all at one time. These scale formats may only be reliably used with a quality HIGH SPEED RS232 Serial Interface.
Suggested Solutions:
1. Replace your Serial Port adapter with a HIGH SPEED Serial Adapter or Converter.
2. As a possible alternative, go to the Windows Control Panel under System, Hardware, turn OFF FIFO and LIFO support on the serial port you are using. Contact your computer hardware expert for more details if needed.